Troubleshooting an HVAC control board requires a systematic, safety-first approach using proper diagnostic tools like a digital multimeter. First, ensure the system power is switched off at the breaker, remove the access panel, and visually inspect the board for obvious signs of damage such as burnt traces, swollen capacitors, or water stains. Next, restore power carefully and check the diagnostic LED status lights flashing on the board, referencing the manufacturer's diagnostic code chart printed on the service panel door. Use your multimeter to verify that line voltage is entering the transformer and that correct low-voltage twenty-four-volt power is reaching the R and C terminals. Test thermostat inputs by jumpering R to G, Y, and W to verify if the board correctly energizes the blower, compressor, and heating relays.