Yes, having the toilet flange positioned slightly above the finished floor level (up to about 1/4 to 1/2 inch) is actually ideal and recommended. A slightly raised flange ensures that when the toilet is set down, the wax ring seal compresses firmly against the bottom of the porcelain bowl, creating a secure watertight and gas-tight barrier. If the flange sits too low below the floor level, it requires thick or stacked wax rings to bridge the gap, which frequently leads to base leaks. Verification: Check that the porcelain bowl rests completely solid and level on the floor without rocking when tightened.
1 votes
Marked as accepted